Published in

MDPI, Applied Sciences, 3(9), p. 501, 2019

DOI: 10.3390/app9030501

Links

Tools

Export citation

Search in Google Scholar

Detection of Pneumatic Conveying by Acoustic Emissions

Journal article published in 2019 by Liansuo An, Weilong Liu ORCID, Yongce Ji, Guoqing Shen, Shiping Zhang
This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

The acoustic emission (AE) method is used in certain industries for the measurement of pneumatic conveying. Instead of the non-intrusive sensors, the comparison of two different intrusive probes in pneumatic conveying is presented in this work, and the AE signals generated by the flow for different particle flow rates and particle sizes were studied. Comparing the distribution of root mean square (RMS) values indicates that the AE signal acquired by a wire mesh probe was more reliable than that from a T-type probe. Limited intrinsic mode functions (IMFs) were extracted from the raw signals by the ensemble empirical mode decomposition (EEMD) algorithm. The characteristics of these signals were analyzed in both the time and frequency domains, and the energies of different IMFs were used to predict the particle mass flow rates, demonstrating a relative error under 10% achieved by the proposed monitoring system. Additionally, the mean squared error contribution fraction, instead of the energy fraction, can predict the particle size.