Published in

IWA Publishing, Water Science and Technology, 1(76), p. 115-123, 2017

DOI: 10.2166/wst.2017.118

Links

Tools

Export citation

Search in Google Scholar

Monitoring accumulation sediment characteristics in full scale sewer physical model with urban wastewater

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

A series of experiments were carried out with real wastewater in a pilot flume located at A Coruña wastewater treatment plant (WWTP) (Spain). A full scale model was developed to test a circular (300 mm inner diameter) and an equivalent area egg-shaped plastic pipe under controlled experimental conditions (pipe slope 2–5‰, averaged discharge Q = 4 L/s). Velocity profiles and sediment accumulation in the pipe invert was daily measured. Within the 7–11 days, the average sediment accumulation rate found in the circular pipe was between 1.4 and 3.8 mm/d. The sediment height depended on the input wastewater sediment distribution and organic content. The egg-shaped pipe presented no sediment deposit for the same downstream boundary conditions, although biofilms were attached to the walls of both pipes. Besides, wastewater quality was monitored continuously and sediment composition was studied at the end of experiments. Two types of sediment were recorded: a granular bed deposit (ρ = 1,460 kg/m3, d50 = 202 μm) and wall biofilms (ρ = 1,190 kg/m3, d50 = 76 μm).