Published in

Elsevier, Journal of Chromatography B, 24(877), p. 2493-2498

DOI: 10.1016/j.jchromb.2009.06.022

Links

Tools

Export citation

Search in Google Scholar

Determination of the antifungal agent posaconazole in human serum by HPLC with parallel column-switching technique

This paper was not found in any repository, but could be made available legally by the author.
This paper was not found in any repository, but could be made available legally by the author.

Full text: Unavailable

Green circle
Preprint: archiving allowed
Red circle
Postprint: archiving forbidden
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Posaconazole is a new broad-spectrum antifungal agent that is currently only available as an oral suspension and shows high intra- and inter-individual differences in oral bioavailibility. Pre-existing methods for the determination of the substance involve the use of internal standards or require a quite complicated and time-consuming sample pre-treatment. Our HPLC method is fast and fully-automated and there is no need for any manual sample pre-treatment. On-line transfer of posaconazole from the extraction column was followed by chromatographic separation on a C18 column and fluorescence detection (lambda(ex): 261 nm, lambda(em): 357 nm). Retention time of posaconazole was about 11.7 min, the lower limit of quantification was found to be 0.1 mg/l. A linear calibration curve was obtained over the concentration range of 0.1-5 mg/l using a 50 microl sample (r(2)=0.999). The relative standard deviations of intra-day variations ranged from 2.3% to 9.4%, intra-day accuracy from 88.8% to 114.8%. ; Posaconazole is a new broad-spectrum antifungal agent that is currently only available as an oral suspension and shows high intra- and inter-individual differences in oral bioavailibility. Pre-existing methods for the determination of the substance involve the use of internal standards or require a quite complicated and time-consuming sample pre-treatment. Our HPLC method is fast and fully-automated and there is no need for any manual sample pre-treatment. On-line transfer of posaconazole from the extraction column was followed by chromatographic separation on a C18 column and fluorescence detection (λex: 261 nm, λem: 357 nm). Retention time of posaconazole was about 11.7 min, the lower limit of quantification was found to be 0.1 mg/l. A linear calibration curve was obtained over the concentration range of 0.1–5 mg/l using a 50 μl sample (r2 = 0.999). The relative standard deviations of intra-day variations ranged from 2.3% to 9.4%, intra-day accuracy from 88.8% to 114.8%.