Links

Tools

Export citation

Search in Google Scholar

A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Question mark in circle
Preprint: policy unknown
Question mark in circle
Postprint: policy unknown
Question mark in circle
Published version: policy unknown

Abstract

Hung-Yuan Lin,1–3 Yi-Ting Fang,4 Ya-Jung Chuang,5 Justin N Karlin,6 Hsin-Yang Chen,7 Szu-Yuan Lin,8 Pi-Jung Lin,9 Ming Chen10 1Universal Eye Center, Zhong-Li, Taiwan, Republic of China; 2Department of Optometry, Central Taiwan University of Science and Technology, Taichung, Taiwan, Republic of China; 3Department of Ophthalmology, Fu-Jian Medical University, People’s Republic of China; 4Universal Eye Center, Taoyuan, Taiwan, Republic of China; 5Universal Eye Center, Long-Tan, Taiwan, Republic of China; 6Department of Ophthalmology, University of Virginia, Charlottesville, VA, USA; 7Department of Ophthalmology, Ningbo First Hospital, People’s Republic of China; 8Department of Ophthalmology, Cathay General Hospital, 9Universal Eye Center, Taipei, Taiwan, Republic of China; 10Department of Surgery, Division of Ophthalmology, John A Burns School of Medicine, University of Hawaii, Honolulu, HI, USA Abstract: During toric intraocular lens (IOL) implantation, surgeons must take particular care to ensure that inaccurate preoperative measurement and intraoperative misalignment do not cause unexpected postoperative residual astigmatism. This retrospective, comparative case series study aimed to analyze the rotational deviation, or cyclotorsion, of three corneal marking methods: VERION digital marker (VDM; reference), horizontal slit beam marking (HSBM), and subjective direct visual marking (SDVM) on the table (using a bevel knife tip). Subjects included 81 eyes of 61 patients (mean age: 65.70±13.14 years; range: 32–91 years) undergoing scheduled cataract surgery. A preoperative reference image was taken of each eye. Subsequently, a slit lamp with the light beam turned to the horizontal meridian was used to align the seated patient’s head, and two reference marks were placed at the 3- and 9-o’clock positions of the corneal limbus using a 27-gauge needle and marking pen (HSBM). Upon transfer to the surgical table, the VDM was used to display a real-time dial scale on the patient’s eye, with the entrance of the temporal clear corneal incision (CCI) at 0° (horizontal meridian). Simultaneously, a bevel knife tip was used to create a marker based on the surgeon’s visual determination of the temporal 0° point (SDVM). We used the VDM to quantitatively evaluate the accuracy of axis alignment via deviation from the horizontal reference meridian. Compared with the reference meridian, the SDVM (–3.46°±7.32°, range: –18° to 13°) exhibited greater average relative cyclotorsion versus the HSBM (0.41°±4.92°, range: –10° to 10°). Furthermore, the mean average misalignment was significantly less in the HSBM group versus the SDVM group (t=4.179, P