Published in

Royal Society of Chemistry, Journal of Environmental Monitoring, 3(13), p. 657, 2011

DOI: 10.1039/c0em00472c

Links

Tools

Export citation

Search in Google Scholar

Seasonal evaluation of outdoor/indoor air quality in primary schools in Lisbon

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

The aim of this study was to evaluate the indoor (I) and outdoor (O) levels of NO₂, speciated volatile organic compounds (VOCs) and carbonyls at fourteen primary schools in Lisbon (Portugal) during spring, autumn and winter. Three of these schools were also selected to be monitored for comfort parameters, such as temperature and relative humidity, carbon dioxide (CO₂), carbon monoxide (CO), total VOCs, and both bacterial and fungal colony-forming units per cubic metre. The concentration of CO₂ and bioaerosols greatly exceeded the acceptable maximum values of 1800 mg m⁻³ and 500 CFU m⁻³, respectively, in all seasons. Most of the assessed VOCs and carbonyls occurred at I/O ratios above unity in all seasons, thus showing the importance of indoor sources and building conditions in indoor air quality. However, it has been observed that higher indoor VOC concentrations occurred more often in the colder months, while carbonyl concentrations were higher in the warm months. In general, the I/O NO₂ ratios ranged between 0.35 and 1, never exceeding the unity. Some actions are suggested to improve the indoor air quality in Lisbon primary schools.