Preliminary Safety Analysis of the IRIS Reactor

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

A deterministic analysis of the IRIS safety features has been carried out by means of the best-estimate code RELAP (ver. RELAP5 mod3.2). First, the main system components were modeled and tested separately, namely: the Reactor Pressure Vessel (RPV), the modular helical-coil Steam Generators (SG) and the Passive (natural circulation) Emergency Heat Removal System (PEHRS). Then, a preliminary set of accident transients for the whole primary and safety systems was investigated. Since the project was in a conceptual phase, the reported analyses must be considered preliminary. In fact, neither the reactor components, nor the safety systems and the reactor signal logics were completely defined at that time. Three 'conventional' design basis accidents have been preliminary evaluated: a Loss Of primary Flow Accident, a Loss Of Coolant Accident and a Loss Of Feed Water accident. The results show the effectiveness of the safety systems also in LOCA conditions; the core remains covered for the required grace period. This provides the basis to move forward to the preliminary design. (authors)