Published in

BioMed Central, Respiratory Research, 1(16), 2015

DOI: 10.1186/s12931-015-0269-4

Links

Tools

Export citation

Search in Google Scholar

The Tiotropium Safety and Performance in Respimat® (TIOSPIR®) Trial: Spirometry Outcomes

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Abstract Background Tiotropium Safety and Performance in Respimat® (TIOSPIR®) compared the safety and efficacy of tiotropium Respimat® and tiotropium HandiHaler® in patients with chronic obstructive pulmonary disease (COPD). A prespecified spirometry substudy compared the lung function efficacy between treatment groups. Methods TIOSPIR® was a large-scale, long-term (2.3-year), event-driven, randomized, double-blind, parallel-group trial of 17,135 patients with COPD. In the spirometry substudy, trough forced expiratory volume in 1 second (FEV1) and forced vital capacity (FVC) were measured at baseline and every 24 weeks for the duration of the trial. Results The substudy included 1370 patients who received once-daily tiotropium Respimat® 5 μg (n = 461), 2.5 μg (n = 464), or tiotropium HandiHaler® 18 μg (n = 445). Adjusted mean trough FEV1 (average 24–120 weeks) was 1.285, 1.258, and 1.295 L in the Respimat® 5 μg, 2.5 μg, and HandiHaler® 18 μg groups (difference versus HandiHaler® [95 % CI]: −10 [−38, 18] mL for Respimat® 5 μg and, −37 [−65, −9] mL for Respimat® 2.5 μg); achieving noninferiority to tiotropium HandiHaler® 18 μg for tiotropium Respimat® 5 but not for 2.5 μg (prespecified analysis). Adjusted mean trough FVC was 2.590, 2.544, and 2.593 L in the Respimat® 5 μg, 2.5 μg, and HandiHaler® 18 μg groups. The rates of FEV1 decline over 24 to 120 weeks were similar for the three treatment arms (26, 40, and 34 mL/year for the tiotropium Respimat® 5-μg, 2.5-μg, and HandiHaler® 18-μg groups). The rate of FEV1 decline in GOLD I + II patients was greater than in GOLD III + IV patients (46 vs. 23 mL/year); as well as in current versus ex-smokers, in patients receiving combination therapies at baseline versus not, and in those experiencing an exacerbation during the study versus not. Conclusions The TIOSPIR® spirometry substudy showed that tiotropium Respimat® 5 μg was noninferior to tiotropium HandiHaler® 18 μg for trough FEV1, but Respimat® 2.5 μg was not. Tiotropium Respimat® 5 μg provides similar bronchodilator efficacy to tiotropium HandiHaler® 18 μg with comparable rates of FEV1 decline. The rate of FEV1 decline varied based on disease severity, with a steeper rate of decline observed in patients with moderate airway obstruction. Trial registration NCT01126437 .