BioMed Central, BMC Geriatrics, 1(10), 2010
Full text: Download
Abstract Background Previous studies in long-term care (LTC) have demonstrated that warfarin management is suboptimal with preventable adverse events often occurring as a result of poor International Normalized Ratio (INR) control. To assist LTC teams with the challenge of maintaining residents on warfarin in the therapeutic range (INR of 2.0 to 3.0), we developed an electronic decision support system that was based on a validated algorithm for warfarin dosing. We evaluated the MEDeINR system in a pre-post implementation design by examining the impact on INR control, testing frequency, and experiences of staff in using the system. Methods For this feasibility study, we piloted the MEDeINR system in six LTC homes in Ontario, Canada. All128 residents (without a prosthetic valve) who were taking warfarin were included. Three-months of INR data prior to MEDeINR was collected via a retrospective chart audit, and three-months of INR data after implementation of MEDeINR was captured in the central computer database. The primary outcomes compared in a pre-post design were time in therapeutic range (TTR) and time in sub/supratherapeutic ranges based on all INR measures for every resident on warfarin. Secondary measures included the number of monthly INR tests/resident and survey/focus-group feedback from the LTC teams. Results LTC homes in our study had TTR's that were higher than past reports prior to the intervention. Overall, the TTR increased during the MEDeINR phase (65 to 69%), but was only significantly increased for one home (62% to 71%, p