Published in

SAGE Publications, Neuroradiology Journal, The, 6(34), p. 593-599, 2021

DOI: 10.1177/19714009211017782

Links

Tools

Export citation

Search in Google Scholar

High-resolution vessel wall imaging after mechanical thrombectomy

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Objectives High-resolution magnetic resonance imaging has the potential of characterising arterial wall changes after endovascular mechanical thrombectomy. The purpose of this study is to evaluate high-resolution magnetic resonance imaging features of large intracranial arteries following mechanical thrombectomy. Methods Patients who presented with acute ischaemic stroke due to large vessel occlusion and underwent mechanical thrombectomy were prospectively recruited. Subjects underwent high-resolution magnetic resonance imaging within 24 hours of the procedure. Magnetic resonance imaging sequences included whole brain T1 pre and post-contrast black-blood imaging, three-dimensional T2, contrast-enhanced magnetic resonance angiography and susceptibility-weighted imaging. Arterial wall enhancement was objectively assessed after normalisation with the pituitary stalk. The contrast ratio of target vessels was compared with non-affected reference vessels. Results Twenty patients with 22 target vessels and 20 reference vessels were included in the study. Sixteen patients were treated with stentriever with or without aspiration, and four with contact aspiration only. Significantly higher arterial wall enhancement was identified on the target vessel when compared to the reference vessel (U = 22.5, P < 0.01). The stentriever group had an 82% increase in the contrast ratio of the target vessel (x̄ = 0.75 ± 0.21) when compared to the reference vessel (x̄ = 0.41 ± 0.13), whereas the contact aspiration group had a 64% increase of the contrast ratio difference between target (x̄ = 0.62 ± 0.07) and reference vessels (x̄ = 0.38 ± 0.12). Approximately 65% of patients in the stentriever group had a positive parenchymal susceptibility-weighted imaging versus 25% in the contact aspiration group. There was no statistically significant correlation between susceptibility-weighted imaging volume and the percentage increase in the contrast ratio ( rs = 0.098, P = 0.748). Conclusions This prospective pilot study used the objective quantification of arterial wall enhancement in determining arterial changes after mechanical thrombectomy. Preliminary data suggest that the use of stentrievers is associated with a higher enhancement as compared to reperfusion catheters.