Published in

Oxford University Press, Translational Animal Science, 4(4), 2020

DOI: 10.1093/tas/txaa190

Links

Tools

Export citation

Search in Google Scholar

Effects of coated and non-coated steroidal implants on growth performance, carcass characteristics, and serum estradiol-17β concentrations of finishing Holstein steers

Distributing this paper is prohibited by the publisher
Distributing this paper is prohibited by the publisher

Full text: Unavailable

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Abstract The objectives of the study were to determine the effect of coated or noncoated hormone implants on growth performance, carcass characteristics, and serum estradiol-17β (E2) concentrations of Holstein steers fed a grain-based diet for 112 d. Seventy-nine Holstein steers [average initial body weight (BW) = 452 ± 5.5 kg] were stratified by BW and allotted to one of two treatments: 1) Holstein steers implanted with a coated implant containing 200 mg of trenbolone acetate (TBA) and 40 mg E2 (Revalor-XS (Merck Animal Health; Summit, NJ)] on day 0 (XS) or 2) Holstein steers implanted two times (days 0 and 56) with a noncoated implant containing 80 mg of TBA and 16 mg of E2 [(2IS) Revalor-IS (Merck Animal Health)]. Data were analyzed using the MIXED procedure of SAS (SAS Inst. Inc., Cary, NC). There was no effect (P ≥ 0.71) of implant strategy on initial, middle, and final BW. No effect (P ≥ 0.12) of implant strategy was observed on average daily gain, dry matter intake, or gain-to-feed ratio. There were no effects (P ≥ 0.11) of implant strategy on carcass characteristics. There was an implant × day interaction (P < 0.01) for the circulation of serum E2 concentrations. Serum E2 concentration increased similarly 14 d after Holstein steers were implanted, regardless of implant strategy. At 28 d, after steers were implanted, steers in the XS group had less serum E2 concentration than Holstein steers in the 2IS group. However, at 56 d after the first implantation, both groups, once again, had similar serum E2 concentrations and E2 concentrations were less on day 56 than day 28 for both strategies. Holstein steers implanted with 2IS had greater serum E2 concentration on day 70 and E2 concentrations remained greater than serum E2 of Holstein steers implanted XS for the duration of the trial (day 112). In summary, there was no effect of coated or two doses of noncoated implant on growth performance or carcass characteristics of Holstein steers.