Published in

MDPI, Journal of Clinical Medicine, 8(9), p. 2551, 2020

DOI: 10.3390/jcm9082551

Links

Tools

Export citation

Search in Google Scholar

Load-Bearing Detection with Insole-Force Sensors Provides New Treatment Insights in Fragility Fractures of the Pelvis

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Background: Due to an aging society, more and more surgeons are confronted with fragility fractures of the pelvis (FFPs). The aim of treatment of such patients should be the quickest possible mobilization with full weight-bearing. Up to now however, there are no data on loading of the lower extremities in patients suffering FFPs. We hypothesized to find differences in loading of the lower limbs. Methods: 22 patients with a mean age of 84.1 years were included. During gait analysis with insole-force sensors, loading on the lower extremities was recorded during early mobilization after index fracture. Results: Especially the average peak force showed differences in loading, as the affected limb was loaded significantly less {59.78% (SD ± 16.15%) of the bodyweight vs. 73.22% (SD ± 14.84%) (p = <0.001, effect size r = 0.58)}. Furthermore, differences in loading in between the fracture patterns of FFPs were observed. Conclusion: This study shows that it is possible to reliably detect the extremity load, with the help of an insole device, in patients presenting with fragility fractures of the pelvis. There is great potential to improve the choice and time of treatment with insole-force sensors in FFPs in future.