BioMed Central, BMC Research Notes, 1(4), 2011
Full text: Download
Abstract Background To determine the time and temperature stability of whole blood lactate using experimental conditions applicable to the out-of-hospital environment. Findings We performed a prospective, clinical laboratory-based study at an academic hospital. Whole blood lactate was obtained by venipuncture from five post-prandial, resting subjects. Blood was stored in lithium heparinized vacutainers in three temperature conditions: 1) room temperature (20??C), 2) wrapped in a portable, instant ice pack (0??C), or 3) wet ice (0??C). Lactate concentrations (mmol/L) were measured at 0, 5, 10, 20, and 30 minutes after sampling, and compared using repeated measures analysis of variance. Mean baseline lactate among resting subjects (N = 5) was 1.24 mmol/L (95%CI: 0.49,1.98 mmol/L). After 30 minutes, lactate concentration increased, on average, by 0.08 mmol/L (95%CI: 0.02,0.13 mmol/L), 0.18 mmol/L (95%CI: 0.07,0.28 mmol/L), and 0.36 mmol/L (95%CI: 0.24,0.47 mmol/L) when stored in wet ice, ice pack, and room temperature, respectively. The increase in lactate was similar in samples wrapped in portable ice pack or stored in wet ice at all time points (p > 0.05), and met criteria for equivalence at 30 minutes. However, lactate measurements from whole blood stored at room temperature were significantly greater, on average, than wet ice or portable ice pack within five and ten minutes, respectively (p