Published in

MDPI, Metabolites, 1(7), p. 7

DOI: 10.3390/metabo7010007

Links

Tools

Export citation

Search in Google Scholar

QSRR Modeling for Metabolite Standards Analyzed by Two Different Chromatographic Columns Using Multiple Linear Regression

This paper is made freely available by the publisher.
This paper is made freely available by the publisher.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Green circle
Published version: archiving allowed
Data provided by SHERPA/RoMEO

Abstract

Modified quantitative structure retention relationships (QSRRs) are proposed and applied to describe two retention data sets: A set of 94 metabolites studied by a hydrophilic interaction chromatography system under organic content gradient conditions and a set of tryptophan and its major metabolites analyzed by a reversed-phase chromatographic system under isocratic as well as pH and/or simultaneous pH and organic content gradient conditions. According to the proposed modification, an additional descriptor is added to a conventional QSRR expression, which is the analyte retention time, tR(R), measured under the same elution conditions, but in a second chromatographic column considered as a reference one. The 94 metabolites were studied on an Amide column using a Bare Silica column as a reference. For the second dataset, a Kinetex EVO C18 and a Gemini-NX column were used, where each of them was served as a reference column of the other. We found in all cases a significant improvement of the performance of the QSRR models when the descriptor tR(R) was considered.