Published in

Elsevier, The Annals of Thoracic Surgery, 2(103), p. 676-686

DOI: 10.1016/j.athoracsur.2016.08.072

Links

Tools

Export citation

Search in Google Scholar

Clinical Safety and Effectiveness of Endoaortic as Compared to Transthoracic Clamp for Small Thoracotomy Mitral Valve Surgery: Meta-Analysis of Observational Studies.

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Red circle
Postprint: archiving forbidden
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Other ; Controversies remain on the increased rate of neurological events after small thoracotomy mitral valve surgery attributed to endoaortic balloon occlusion (EABO). Systematic literature search of databases identified 17 studies enrolling 6,643 patients comparing safety and effectiveness of EABO versus transthoracic clamp. In a meta-analysis, there was no difference in occurrence of cerebrovascular events, all-cause mortality, and kidney injury. EABO was associated with a significantly higher risk of iatrogenic aortic dissection (0.93% versus 0.13%; risk ratio, 4.67; 95% confidence interval, 1.62 to 13.49; p = 0.004) and a trend toward longer operative times. The data is limited to observational studies.