Published in

Institute of Electrical and Electronics Engineers, Journal of Microelectromechanical Systems, 3(19), p. 675-682, 2010

DOI: 10.1109/jmems.2010.2046014

Links

Tools

Export citation

Search in Google Scholar

Development and Application of a Novel Microfabricated Device for the In Situ Tensile Testing of 1-D Nanomaterials

This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Green circle
Postprint: archiving allowed
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

We report on the development and application of a silicon microdevice for the in situ quantitative mechanical characterization of single 1-D nanomaterials within a scanning electron microscope equipped with a quantitative nanoindenter. The design makes it possible to convert a compressive nanoindentation force applied to a shuttle to uniaxial tension on a specimen attached to a sample stage. Finite-element analysis and experimental calibration have been employed to extract the specimen stress versus strain curve from the indentation load versus displacement curve. The stress versus strain curves for three 200-300-nm-diameter Ni nanowire specimens are presented and analyzed.