Published in

Wiley, Structural Control and Health Monitoring, 2-3(13), p. 573-588, 2006

DOI: 10.1002/stc.99

Links

Tools

Export citation

Search in Google Scholar

Smart Base Isolated Benchmark Building, part I: Problem Definition

Journal article published in 2006 by S. Narasimhan, S. Nagarajaiah ORCID, E. A. Johnson, H. P. Gavin
This paper is available in a repository.
This paper is available in a repository.

Full text: Download

Green circle
Preprint: archiving allowed
Orange circle
Postprint: archiving restricted
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

This paper presents the benchmark problem definition for seismically excited base-isolated buildings. The objective of this benchmark study is to provide a well-defined base-isolated building with a broad set of carefully chosen parameter sets, performance measures and guidelines to the participants, so that they can evaluate their control algorithms. The control algorithms may be passive, active or semi-active. The benchmark structure considered is an eight-storey base-isolated building similar to existing buildings in Los Angeles, California. The base isolation system includes both linear and nonlinear bearings and control devices. The superstructure is considered to be a linear elastic system with lateral–torsional behavior. A new nonlinear dynamic analysis program has been developed and made available to facilitate direct comparison of results of different control algorithms. Copyright © 2005 John Wiley & Sons, Ltd.