Published in

American Chemical Society, Environmental Science and Technology, 24(38), p. 6817-6823, 2004

DOI: 10.1021/es049710l

Links

Tools

Export citation

Search in Google Scholar

Investigation of Conventional Membrane and Tangential Flow Ultrafiltration Artifacts and Their Application to the Characterization of Freshwater Colloids

Journal article published in 2004 by Matthew A. Morrison, Gaboury Benoit
This paper was not found in any repository; the policy of its publisher is unknown or unclear.
This paper was not found in any repository; the policy of its publisher is unknown or unclear.

Full text: Unavailable

Green circle
Preprint: archiving allowed
  • Must obtain written permission from Editor
  • Must not violate ACS ethical Guidelines
Orange circle
Postprint: archiving restricted
  • Must obtain written permission from Editor
  • Must not violate ACS ethical Guidelines
Red circle
Published version: archiving forbidden
Data provided by SHERPA/RoMEO

Abstract

Artifacts associated with the fractionation of colloids in a freshwater sample were investigated for conventional membrane filtration (0.45 micron cutoff), and two tangential flow ultrafiltration cartridges (0.1 micron cutoff and 3000 MW cutoff). Membrane clogging during conventional filtration removed some colloids smaller than 0.1 micron in diameter, much smaller than the nominal size of the filter. For certain constituents (e.g., Fe), filter clogging had a significant effect on filtrate concentrations, while artifacts associated with tangential flow ultrafiltration using 0.1 micron cutoff were minimal. Artifacts occurred during tangential flow ultrafiltration with a 3000 MW cutoff, but did not deviate from predicted changes in concentration based on a standard permeation model. Comparison of filtrate concentrations for membrane filtration (at 1.0 and 0.45 micron) and tangential flow ultrafiltration (at 0.1 micron) for a large number of samples from Connecticut rivers shows that significant and consistent differences exist between their separation characteristics. Results for organic carbon, Fe, Mn, Al, Cu, and Pb demonstrate the magnitude of the effects of the fractionation technique on filtrate element concentration, show variability by element and flow condition, and highlight the importance of larger colloids to freshwater metal speciation. One implication of the research is that tangential flow ultrafiltration with large size cutoff membranes (e.g., 0.1 micron) may be superior to conventional filtration with filters in the same size discrimination range, and potentially more appropriate for the fractionation of natural water samples.